Iridex
Company   Investors   Find a Physician   News   Careers   Germany   Search
Sales: 650.962.8100    Support: 800.388.4747
Facebook  Twitter  LinkedIn  YouTube  Instagram
  • Home
  • Products
    • Lasers
      • Cyclo G6
      • OcuLight
      • IQ 532
      • IQ 577
    • Retinal Surgical Instruments
      • Laser Probes
      • Consumables
    • Veterinary
    • Retina Delivery Devices
      • LIO
      • TxCell
    • Glaucoma Devices
      • MicroPulse P3 Device
      • Revised MicroPulse P3
      • G-Probe
      • G-Probe Illuminate
      • MicroPulse Laser Trabeculoplasty (MLT) Lens
    • ENT
    • Accessories
      • Vexio Cart
  • MicroPulse
  • PASCAL®
    • Iridex PASCAL ®
    • PASCAL® Synthesis
  • Physician Education
    • Glaucoma
      • Library
      • MicroPulse P3 - CYCLO G6
      • TSCPC G-Probe
    • Retina
      • Age-Related Macular Degeneration
      • Central Serous Chorioretinopathy
      • Diabetic Macular Edema
      • ME due to RVOs
      • ROP
      • Vitreoretinal Surgery
    • Testimonials
    • Certification
    • Webinars
    • Seminars
    • Articles
    • Manuals
  • Patient Education
    • Treat My DME
    • Treat My Glaucoma
    • Understanding ROP
    • Find A Physician
  • Contact
    • Contact Us
    • Ask A Question
    • Ask Tech Support
    • Schedule A Demo
    • Request A Quote
    • International Distributors
HOME > Products > Glaucoma Devices > G-Probe ...

G-Probe® Delivery Device

Continuous-Wave Transscleral cyclophotocoagulation (CWTSCPC) using the G-Probe Delivery Device is a long-term, effective intraocular pressure (IOP) lowering procedure for many types of glaucoma patients.1-3 Patients with refractory glaucoma and those with good visual acuity can benefit from CWTSCPC using the G-Probe.


g probe

Other Glaucoma Products

  • Cyclo G6® Laser
  • MicroPulse® P3 Delivery Device
  • G-Probe Illuminate® Delivery Device
  • MicroPulse Laser Trabeculoplasty (MLT) Lens


Download Cyclo G6 Brochure
Download The Glaucoma Runway Brochure

Download The Surgical Guide

Schedule a hands-on demo

Schedule a no-obligation demo to see for yourself how MicroPulse Technology and Iridex’s Family of Products can take YOUR practice to the next level.

Schedule a demo

Schedule a demo today!

×
  • Overview
  • Studies
  • Surgical Guide
  • Compatible Products
  • Testimonials
  • FAQs
  • Manuals
  • Ordering

The G-Probe® Delivery Device performs Continuous-Wave Transscleral Cyclophotocoagulation (CWTSCPC) to lower IOP through selective ablation of the ciliary processes. This simple, yet effective repeatable procedure can be performed in the office, operating room, or in conjunction with other procedures, like cataract surgery.

STUDIES



 

Transscleral Diode Laser Cyclophotocoagulation

A Comparison of Slow Coagulation and Standard Coagulation Techniques
Eric R.H. Duerr, MD, Richard K. Lee, MD, PhD, et al.

pdf Download Now

 


 

Revisiting TSCPC as an Option
Ophthalmology Today

Procedure has ability to lower IOP, preserve vision similar to trabeculectomy and tube shunts

pdf Download Now

 

 

Transscleral cyclophotocoagulation effective as early glaucoma treatment

Although typically a last line of defense, the treatment has shown to be beneficial early in the glaucoma surgical treatment paradigm.
Parag Parekh, MD

pdf Download Now

 


 

Diode Laser Cyclophotocoagulation
Glaucoma Today

Technique and results.

pdf Download Now

 


 

Reconsidering Transscleral Cyclophotocoagulation
Glaucoma Today

pdf Download Now

 


 

The Benefits of Transscleral Cyclophotocoagulation
Glaucoma Today

This viable alternative to trabeculectomy should be considered in more moderate to severe glaucoma cases

pdf Download Now

 


 
 

Article G-Probe vs. ECP
Glaucoma Today

pdf Download Now

Continuous-Wave Transscleral Cyclophotocoagulation (CW-TSCPC) Using the Cyclo G6®, G-Probe®* and G-Probe Illuminate®*

Treatment Parameters & Techniques Based on Guidance from Dr. Gaasterland, et al.1, 2


G-Probe PlacementWhen using the G-Probe and G-Probe Illuminate devices with the Cyclo G6 laser:

G-Probe Application
     
  1. Keep the probe tip and the eye surface moist throughout the procedure.
  2. Hold the G-Probe parallel to the visual axis with the shorter edge of the footplate firmly between the anterior border and the middle of the limbus.
  3. Do not treat over sites of previous trabeculectomies. Avoid areas of heavy perilimbal pigmentation.
  4. Spaced one-half the width of the G-Probe footplate by aligning the side of the G-Probe over the indented center of the adjacent application.
  5. Treat 270o (three quadrants) with 18-21 applications per treatment session, usually omitting the temporal quadrant.

Classic Technique1

Laser Power 2000 mW
Duration 2000 ms
Laser Applications: 18-21 Spots

If you hear a “pop”, adjust laser power down 250 mW per application until you do not hear a “pop.” Then continue the applications at that power or until you hear another “pop.”

Slow-Burn Technique2

Dark Pigmentation

Dark Skin Pigmentation/Dark Colored Irises

Laser Power 1250 mW
Duration 4000 ms
Laser Applications: 18-21 Spots

Light Pigmentation

Light Skin Pigmentation/Light Colored Irises

Laser Power 1500 mW
Duration 3500 ms
Laser Applications: 18-21 Spots

Usually no, or few ‘pops’ will be heard.

Retreatment

Begin retreatment 45° from the initial treatment. The second 270° treatment will cover a half of the untreated quadrant, plus two and a half quadrants from the earlier treatment.

  1. Kosoko O, Gaasterland DE, Pollack IP, Enger CL: Long-Term Outcome of Initial Ciliary Ablation with Contact Diode Laser Transscleral Cyclophotocoagulation for Severe Glaucoma. The Diode Laser Ciliary Ablation Study Group. Ophthalmology 1996;103(8):1294-302.
  2. Gaasterland DE: Diode Laser Cyclophotocoagulation. Technique and Results. Glaucoma Today 2009;(March):35-38.

COMPATIBLE PRODUCTS


The G-Probe device is powered by the Cyclo G6 Laser. The Cyclo G6 Laser is an 810 nm infrared laser. It was launched in 2015, it is available in more than 60 countries, and it is used in 38 of the 39 best hospitals in the United States.* The Cyclo G6 Laser can be use in MicroPulse mode with the MicroPulse P3 Device and in continuous wave mode with the G-Probe Device and the G-Probe Illuminate Device.

*As ranked by U.S. News and World Report

PHYSICIAN TESTIMONIALS


kammer

You can really consider TSCPC in almost all glaucoma situation, even malignant glaucoma. It is not just relegated to end-stage treatment anymore.

Dr. Jeffrey Kammer | Nashville, TN | Vanderbilt Eye Institute

kammer

TSCPC is a surgery that can be done before or after any other surgery. It is very versatile from that standpoint.

Dr. Nathan Radcliffe | New York, NY | Weill Cornell Medical College

Dr. Steven Vold

Recovery with TSCPC is much more rapid and the postoperative care much less involved than with someone who has had an incisional glaucoma case in a surgical center.

Dr. Steven Vold | Springdale, AR | Vold Vision, PLLC

FREQUENTLY ASKED QUESTIONS


1. What is the treatment technique for the G-Probe® Glaucoma Device?

For additional detailed instructions please refer to the Iridex G-Probe Instrumentation Instructions for Use.

2. What is the shelf life?

Three years

3. Is the G-Probe Device a single-use devices?

Yes, the G-Probe device has been validated for single use only.

4. What is the CPT code?

The CPT code for cyclophotocoagulation is 66710

5. What are the reimbursement rates for 66710?

National reimbursement for CPT code 66710 in the United States is as follows: $453 for physician payment in physician office, $400 for physician payment in ASC, $836 for facility payment in ASC, $400 for physician payment in hospital outpatient department, and $1,934 for facility payment in hospital outpatient department. Please consult your local Medicare and non-Medicare carriers for local rates and for coverage and payment policies

 

G-Probe Operator Manual

View Manual

ORDERING


To order the G-Probe Device, speak with your local sales representative, distributor, email us at customerservice@iridex.com, or call us at +1.650.962.8100

  • The part number is 15980
  • Six probes are included in a box
  • The G-Probe Device is a single-use device
  1. Wilensky JT, Kammer J. Long-term visual outcome of transscleral laser cyclotherapy in eyes with ambulatory vision. Ophthalmology. 2004;111(7):1389-1392.
  2. Egbert PR, Fiadoyor S, Budenz DL, et al. Diode laser transscleral photocoagulation as a primary surgical treatment for primary open angle glaucoma. Arch Ophthalmol. 2001;119:345-350.
  3. Roctchford AP, Jayasawi R, Madhusuhan S, et al. Transscleral diode laser cycloablation in patients with good vision. Br J Ophthalmol. 2010;94(9):1130-1183.

Products

Lasers
Delivery Devices
Retina Consumables
Glaucoma Device

Resources

Physician Information
Patient Information
Seminars
Webinars

About Iridex

Overview
Testimonials
Iridex Cares
Newsletters
Contact Us

Company

Investors
Distributors
Careers
News
Events

twitter facebook linkedin youtuber
Copyright ©2003-2026 by Iridex Corporation
Terms of Use    Privacy Statement