GreenTip Soft Tip Cannula
Effectively visualize and assess the proximity of the retina with the “fluorescing” GreenTip cannula. Unlike transparent silicone-tipped needles, the GreenTip is designed to provide optimal contrast against the red-orange background of the retina.
Gain More Control with Better Visualization
- Patented green tip design maximizes visualization against retina
-
Atraumatic silicone tip protects the retina during aspiration and subretinal fluid drainage
-
Standard tip design maximizes flow
-
Brush tip design protects the tissue by directing partial flow along the side of the tip
-
New 0.5 mm standard tip allows for easy insertion and improved fit in valved cannulas*
-
Available in 0.5mm, 1.0mm, 2.0mm, and 2.5mm lengths
*U.S. Patents: 6,800,076; 7,537,593; 8,177,777
MoistAir™ In-Line Air Humidifier
Enhanced surgical performance by reducing dehydrating effects of dry air in the posterior chamber with the MoistAir humidifier.1,2
Peer-reviewed studies show:
- Delayed crystalline lens feathering3
- May prevent visual of field defects after macular hole surgery3,4
- Protection of the corneal endothelium6,7
The MoistAir chamber inserts into any standard tubing and is self-priming when placed between the stop cock and infusion cannula.
- Harlan JB, Jr., Lee ET, Jensen PS, de Juan E, Jr. Effect of humidity on posterior lens opacification during fluid-air exchange. Arch Ophthalmol 1999;117(6):802-4.
- Welch JC. Dehydration injury as a possible cause of visual field defect after pars plana vitrectomy for macular hole. Am J Ophthalmol 1997;124(5):698-9.
- Ohji M, Nao IN, Saito Y, Hayashi A, Tano Y. Prevention of visual field defect after macular hole surgery by passing air used for fluid-air exchange through water. Am J Ophthalmol 1999;127(1):62-6.
- Cekic O, Ohji M, Zheng Y, Hayashi A, Kusaka S, Tano Y. Experimental study of viscoelastic in the prevention of corneal endothelial desiccation injury from vitreal fluid- air exchange. Am J Ophthalmol 2003;135(5):641-7.
- Cekic O, Ohji M, Hayashi A, Fang XY, Kusaka S, Tano Y. Effects of humidified and dry air on corneal endothelial cells during vitreal fluid-air exchange. Am J Ophthalmol 2002;134(1):75-80.
- Cekic O, Ohji M, Hayashi A, Fang XY, Kusaka S, Tano Y. Humidified air effect on pupil size during fluid-air exchange. Retina 2001;21(5):529-31.
- Eter N, Brinken R, Garbe S, Spitznas M. Intraocular humidity immediately after fluid-air exchange in pars plana vitrectomy. Graefes Arch Clin Exp Ophthalmol 2006;244(3):305-8
Endoview™ Sapphire Surgical Contact Lenses* Manufactured from a single-crystal sapphire, the Endoview Sapphire lenses offer clarity and superior visualization over standard quartz lenses. Durability with Superior Performance - Scratch and chip proof
- High refractive index for a wide field viewing
- Increased visualization during fluid-gas exchange
- Reusable
- Wide array of lens models available
| This text will be replaced | | GreenTip™ Soft Tip cannulas Enhanced visualization with the 'Fluorescing' GreenTip cannula. | This text will be replaced | | MoistAir™ Humidifier Chamber Reduces the effects of dry air in the posterior chamber. |
20 Gauge - Standard Tip 0.5 mm
20 Gauge - Standard Tip 1.0 mm
20 Gauge - Standard Tip 2.5 mm
20 Gauge - Brush Tip 2.5 mm
|
|
100-31
100-40
100-49
100-48 |
23 Gauge - Standard Tip 0.5 mm
23 Gauge - Standard Tip 1.0 mm
23 Gauge - Standard Tip 2.5 mm
23 Gauge - Brush Tip 2.5 mm |
|
100-32
100-41
100-23
100-46 |
25 Gauge - Standard Tip 0.5 mm
25 Gauge - Standard Tip 1.0 mm
25 Gauge - Standard Tip 2.5 mm
25 Gauge - Brush Tip 2.5 mm |
|
100-33
100-42
100-25
100-47 |
| MoistAir Humidifying Chamber |
|
200-10
|
|
|
|